Performing maintenance
LVU-CD-40
en(us)
Page 49 / 68
BeWa LVU-CD-40 4035823a en-us 2016-01-08.doc
2016-01-08
6.
1 - Remove the housing clamp (2400).
2 - Remove the cover by lifting it
upward and set it down to the side.
7.
Remove the element set from the
coalescing housing.
Use both handles to accomplish this.
8.
Rotate the element set on the head by
180°.