Decoding model code
LVU-CD-40
en(us)
Page 62 / 68
BeWa LVU-CD-40 4035823a en-us 2016-01-08.doc
2016-01-08
Decoding model code
LVU - C
D - 40 - G - N - 1 - 1 - E - z - BM - 1 / -
Type
LVU =
LowViscosity
Unit
Function
C
= Filtering and coalescing
Operating fluid
D =
Diesel
Nominal flow rate
40 =
40
l/min
Pump version
G =
Gear
pump
Supply voltage
M
= 230 V AC, 50 Hz, 1 Ph
N
= 400 V AC, 50 Hz, 3 Ph
X
= others on request
Prefilter
1
= Prefilter size 10"
2
= Prefilter size 20"
Water drain
1 =
Manual
2 =
Automatic
Control type
E =
Eco
- with On/Off switch including motor protection
- visual clogging indicator
- manual water drainage
S =
Standard
- with On/Off switch including motor protection
- visual clogging indicator
- manual water drainage
- float switch in the collecting pan
- remote control input On/Off
P =
Standard
- with On/Off switch including motor protection
- programmable operating times
- electrical visual clogging indicator /
- automatic water drainage
- switch-off when "diesel dry"
- float switch in the collecting pan
- remote control input On/Off
Measurement technology
z =
None
Clogging indicator
BM = Differential pressure gauge, visual
D4
= Differential pressure indicator, visual/electrical
Type code
1
= (You always receive the latest type)
Additional
-
= None