Operating / Setting "Standard / Premium" control type
LVU-CD-40
en(us)
Page 41 / 68
BeWa LVU-CD-40 4035823a en-us 2016-01-08.doc
2016-01-08
Adjusting the time selector switch
The operating duration is set at the time selector switch.
Icon
Time setting
1 hour
2 hours
4 hours
8 hours
Checking the motor protection switch
The motor protection switch is aligned and adjusted at the installed electric
motor at the works. It is not necessary to correct the setting. If the motor
protection switch triggers, proceed as indicated in the chapter "Status LED /"
on page 54.
Switching unit on/off
Switch the unit on at the main switch (610) and select the operating duration
using interval control.
Automatic water drainage
If the water sensor signals > 5 seconds, the drain level has been reached
and the water drain value will be opened for approx. 10 seconds. This will
result in approx. 3 liters of water draining out.