Performing maintenance
LVU-CD-40
en(us)
Page 48 / 68
BeWa LVU-CD-40 4035823a en-us 2016-01-08.doc
2016-01-08
Changing the coalescing elements
To replace the coalescing elements, proceed as follows:
1.
Switch off the unit at the main switch.
2.
Close the INLET (1330) and OUTLET
(2560) ball valves
3.
Depressurize the unit.
Carefully screw the air-vent plug out of
the cover with the aid of a size 10 mm
Allen wrench.
4.
Open the ball valve at the DRAIN
connection (3350) to empty the
coalescing housing.
Collect the free water/oil in a suitable
container and dispose of it in an
environmentally friendly manner.
Once the coalescing housing is
completely emptied, close the
"DRAIN" connection (3350).
5.
Loosen the upper tensioning clamp on
the coalescing housing with a 13 mm
Allen wrench by turning it
counterclockwise.