Unit setup/connection
NOTICE
Danger of tipping over / danger of slipping due to vibrations
The unit will be damaged
►
Prior to operation, place the unit on a stable, horizontal surface.
Place the unit on a horizontal and level surface which is well ventilated.
Install the suction port connection at the lowest part of the tank. This ensures
that the water phase located at the base of the tank is reached.
Install the return line as far as possible from the suction point in order to
obtain an optimum intermixing of the tank contents.
Prepare the unit for operation by following the following steps:
1. Check the connector cable for damage. If the connector cable is
damaged, replace it immediately.
2. Check the connecting lines for leaks. Eliminate any leakages
immediately.
3. Check and insert the filter element. For details, see page 45.
4. Check and insert the coalescing element. For details, see page 48.
5. The unit is ready for the next steps on the following pages.