FCU 8000 series
Error Messages and Troubleshooting
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 92/112
BEWA FCU8000 3109776d en-us 2011-06-10.doc
2011-06-10
Error message
Cause(s)
Remedy
Error in selected
language
The last language selected
and stored in the FCU has
been changed due to an
internal fault.
The internal back-up battery
is dead.
Download the FCU
languages to the FCU
again using the PC
software package FluMoS.
If the fault recurs, send the
FCU to HYDAC for repair.
Reload languages
The internal memory for
languages has been partially
changed due to an internal
fault.
The internal back-up battery
is dead.
Download the FCU
languages to the FCU
again using the PC
software package FluMoS.
If the fault recurs, send the
FCU to HYDAC for repair.
Calibration defect
The calibration values in the
EEPROM have been altered
due to electrical interference.
Send the FCU to HYDAC
for repair.
Device ID defect
Internal device designations
in the EEPROM have been
altered due to electrical
interference.
No measures required, as
these values do not affect
the FCU function.
Send the FCU to HYDAC
for repair.
BSU connected
You are trying to start a
MODE M1 ... M4 for online
operation although a BSU is
connected.
Select a mode for
BottleSampling operation.
No BSU
You are trying to start a
MODE M5 or M6 although
no BSU is connected or
detected.
Check if the plug of the
BSU is plugged into the
FCU -> insert the plug into
the CONTROL port of the
FCU.
Check if the BSU is
switched on -> switch the
BSU on.
If the error is still present,
the BSU is defective.
Contact HYDAC.
No BS reports
selected
You are trying to print a
report that was not
generated with the
BottleSampling Unit.
Select a suitable report in
the menu "Print / Reports"
to print out.