Resolving errors/Eliminating errors
FAM 5
en-US
Page 98 / 148
BEWA FAM5 4166129a en-us 2019-03-04.docx
2019-03-04
24 V pump MIN
Trigger for the
message:
The "Min." switch point in the oil tank of the rotary vane
vacuum pump has been reached. The unit switches to
the reset phase and switches off.
Notification only displays for FAM-5-x-x-x-xx-R-x-x-x-.
Remedy:
Perform the following steps:
S
te
p
Description
1.
Message:
24. V pump min.
2.
Fill the rotary vane vacuum pump with vacuum pump oil. For
details, see page 113.
3.
Acknowledge the error.
4.
Start the unit by pressing the F1 key.
5.
The fault is repaired.
If the failure recurs, even though there is enough vacuum pump
oil between the MIN and MAX markings, first check the float
switch and afterwards the PLC.