Selecting the operating mode
FAM 5
en-US
Page 65 / 148
BEWA FAM5 4166129a en-us 2019-03-04.docx
2019-03-04
Setting times for "Dewater/Filter until" (optional)
This menu is displayed only if an AquaSensor
(FAM-xx-x-x-x-xx-x-x-Axx-…)
and/or a ContaminationSensor CS
(FAM-xx-x-x-x-xx-x-x-xCx-…)
is installed
and is activated in the configuration menu.
Description
Test interval
The amount of time after which the FAM switches back on
to check the contamination of the operating media with the
operating modes "
Dewater until"
and "
Filter until"
.
Factory setting: 60 minutes
Min. duration
The amount of time during which the FAM remains at least
in operation.
If the switch-on limit is reached/exceeded after this time,
the FAM will continue to run until the limit for switch-off is
reached once again.
The FAM switches off again and the test interval runs once
more.
If the limit continues not to be reached after this time, the
FAM will switch off again and the test interval will run once
more.
Factory setting: 10 minutes
INTER-
00:60
hrs
00:10
HOME
Dewater/filter until:
Test interval
Min. duration
4/4
Summary of Contents for FAM 5 FluidAqua Mobil
Page 147: ......