Maintenance
FAM 5
en-US
Page 109 / 148
BEWA FAM5 4166129a en-us 2019-03-04.docx
2019-03-04
Check fault signal lamps
To check the fault signal lamp (2), switch the FAM on at the main switch. The
"Fault" signal lamp then lights up.
Change the air filter
Replace the air filter (3.73) every six months. If the FAM is in a very
dusty/damp environment, the replacement intervals shorten accordingly.
To replace the air filter, proceed as follows:
1.
Unscrew the air filter (3.73) by hand counterclockwise.
2.
Dispose of the used air filter in an environmentally-friendly manner.
3.
Screw in the new air filter (3.73) clockwise by hand and tighten it only
by hand.