Maintenance
FAM 5
en-US
Page 106 / 148
BEWA FAM5 4166129a en-us 2019-03-04.docx
2019-03-04
Maintenance
WARNING
FAM in operation
Danger of bodily injury
►
Switch off the unit before any maintenance
work.See page 56 for details.
The safety of all persons coming into contact with the FAM and the
availability of the unit for use are dependent on regular servicing and
maintenance.
Maintenance intervals
The inspection and maintenance works listed here are necessary conditions
for ensuring both long service life and error-free operation of the FAM.
In addition, you will find further information in the operating manuals
published by the manufacturers of the components which are supplied with
the FAM.
S
ee pag
e
24 h
our
s
/
d
a
ily
500 hour
s
/
m
ont
hl
y
300
0 ho
ur
s
/
ev
er
y
s
ix
m
ont
hs
600
0 ho
ur
s
/
ann
ual
ly
FAM
Check the FAM for any leaks
(visual check).
-
X
Check the screwed fittings to
ensure that they are secure
-
X
Check the measuring equipment /
Vacuum pressure gauge in the
vacuum column /
Differential pressure gauge on the
fluid filter
-
X
Check the fault signal lamps
X
Change the air filter
X