Starting up the unit
FAM 5
en-US
Page 56 / 148
BEWA FAM5 4166129a en-us 2019-03-04.docx
2019-03-04
Switching heater on /Checking setting (FAM-xx-x-x-x-xx-x-H-…)
NOTICE
Oils with high viscosity
Functional issues
►
Set the heater to
≈ 50°C with an oil viscosity ≥ 350 mm²/sec.
If the temperature of the fluid is raised by 10-20°C, then the
dewatering capacity increases by up to 50%. The ideal
temperature for dewatering is approx. ≈ 50 - 60°C
If the "
Heat
" operating mode is set to ON, the desired temperature can be set
using the heater dial.
The markings on the dial correspond to the desired temperature in degrees
Celsius (°C).
-
= Heater OFF
F
= Setting for frost protection
30 … 80
= Temperature in °C
The heater's operating
status is shown on the
display:
•
Heat (NO) = Heater off
•
Heat (Yes) = Heater on
The heater has a safety thermostat to protect against overheating. This
switches off the heater when it reaches 110°C. The safety thermostat has to
be reset manually.
See page 100 for details.
OPERATION
until
until
STOP
Dewater
Filter
Heat
+13.0 %S
+37.4°C
Summary of Contents for FAM 5 FluidAqua Mobil
Page 147: ......