Maintenance
FAM 5
en-US
Page 108 / 148
BEWA FAM5 4166129a en-us 2019-03-04.docx
2019-03-04
Main Filter
Changing the filter element
X
Oil mist separator (optional)
Check the fluid level on the sight
glass and drain it, if required
X
Changing the filter element
X
Heater FAM-5-x-x-x-xx-x-H-x-x-x
Check that the connectors are in
contact and tight
-
X
Clean the heating element
X
Synchronize the electricity
consumption of the heater by
comparing the current values with
those on the type label. (optional)
-
X
Electric System
Check the cable conduits for
damage
-
X
Synchronize the electricity
consumption of the motors by
measuring with the nominal values
on the type labels.
-
X
Perform an electrical safety
inspection in accordance with DIN
VDE 0702 and/or corresponding
national regulation.
-
X
Replace all hoses after no later than 5 years.
All pictures and illustrations in the descriptions are examples. They do not
represent all of the different product variants.
Summary of Contents for FAM 5 FluidAqua Mobil