2019-03-04
Filling/Refilling vacuum pump oil
WARNING
Hot surfaces
Risk of burns
►
Keep away from hot surfaces.
►
Allow the vacuum pump to cool down before
performing any work.
- Screw wrench
= 24 mm
Proceed as follows to fill the vacuum pump:
1.
Switch the unit off at the main switch and
unplug the power connector.
Allow the vacuum pump to cool down.
2.
Remove the threaded coupling (k) to the
plug on the level switch.
Remove the plug (l) for the level switch
upwards.
3.
Unscrew the level switch (m) with a screw
wrench
= 24 mm turning
counterclockwise from the vacuum pump.
Carefully remove the level switch from the
vacuum pump in an upward direction.