6 | Setting up / assembly / integration of the filter unit
HYDAC FILTER SYSTEMS GMBH
50 / 124
BeWa MFU-10P 4391553b en-us
Fig. 18:
Adjusting the feet 44°⇨ 0°
To adjust the two feet from 44° to 0°, proceed as follows:
4.
Fully unscrew both screws counterclockwise with an
Allen key.
5.
Rotate the foot ≈ 22° inwards so that the bores in the
foot can be seen in the other threaded hole at the 0° po-
sition in the filter head.
6.
Rotate the two screws clockwise into the other threaded
holes (position 0°) and tighten them securely with a
3 Nm torque.
NOTICE! Ensure that the screws are located fully in-
side the threaded holes. If the screws protrude out of
the hole, the position has not been chosen correctly.
Select the right position using the hole in the foot.
O
The adjustment of the feet from 44° to 0° is complete.
1
2
3
4
5
6
7
8
9
10
A