HYDAC FILTER SYSTEMS GMBH
Setting up / assembly / integration of the filter unit | 6
BeWa MFU-10P 4391553b en-us
49 / 124
Fig. 17:
Adjusting the feet 0°⇨ 44°
To adjust the two feet from 0° to 44°, proceed as follows:
1.
Fully unscrew both screws counterclockwise with an
Allen key.
2.
Rotate the foot ≈ 22° outwards so that the bores in the
foot can be seen in the other threaded hole at the 22°
position in the filter head.
3.
Rotate the two screws clockwise into the other threaded
holes (position 22°) and tighten them securely with a
3 Nm torque.
NOTICE! Ensure that the screws are located fully in-
side the threaded holes. If the screws protrude out of
the hole, the position has not been chosen correctly.
Select the right position using the hole in the foot.
O
The adjustment of the feet from 0° to 44° is completed.
1
2
3
4
5
6
7
8
9
10
A