HYDAC FILTER SYSTEMS GMBH
Performing Maintenance | 9
BeWa MFU-10P 4391553b en-us
97 / 124
9.6 Protective screen for changing the
ContaminationSensor
The protective screen (531) protects the ContaminationSensor
against clogging. Refer to Chapter
for a suitable set of spare parts.
NOTICE
Protective screen missing / operation without the protective
screen
The ContaminationSensor clogged / blocked
u
Never operate the filter unit without a protective screen up-
stream of the ContaminationSensor.
u
Change the protective screen regularly.
1 Allen key
= 5 mm
1 screwdriver
= 8 x 1 mm
1
2
3
4
5
6
7
8
9
10
A