HYDAC FILTER SYSTEMS GMBH
Performing Maintenance | 9
BeWa MFU-10P 4391553b en-us
93 / 124
9.4.2 Removing/installing the push-in protective screen
1x screwdriver
= 16x2 mm
Fig. 30:
Removing/assembling the push-in strainer
For disassembly, proceed as follows:
ü
Switch off the filter unit and remove the lance from the
reservoir and/or close the shut-off device in order to pre-
vent any subsequent flow of the medium.
1.
Disassemble the suction hose ahead of the inlet connec-
tor.
2.
Use the screwdriver
= 16 x 2 to screw the protective
screen
(711)
out of the connection in counterclockwise
direction.
3.
Remove the O-ring
(712)
.
O
Disassembly of the protective screen is complete.
Proceed as follows to install:
4.
Check the O-ring
(712)
for damage and replace it if nec-
essary.
5.
Insert the O-ring
(712)
into the connector.
6.
Use the screwdriver
= 16 x 2 to screw the protective
screen
(711)
into the connection in clockwise direction.
7.
Install the suction hose.
1
2
3
4
5
6
7
8
9
10
A