![HYDAC ELECTRONIC HMG 3010 User Manual Download Page 79](http://html.mh-extra.com/html/hydac-electronic/hmg-3010/hmg-3010_user-manual_2191361079.webp)
HMG 3010
Page 79
Edition 2013-03-26 - V04 R01
Part No.: 669855
Battery life
(from fully charged)
•
HMG 3010 without sensors
approx. 11 hours
•
HMG 3010 with 2 sensors
approx. 9 hours
•
HMG 3010 with 4 sensors
approx. 7 hours
•
HMG 3010 with 8 sensors
approx. 4 hours
Sampling rates
•
Sampling rate:
0.1 ms .. 1 min
•
Sampling rate:
0.1 ms for a maximum of two sensors (other sensor
inputs inactive); e.g. for pressure peak measurements
The sampling rate which can be set is dependent on the active measurement channels. The
following applies:
•
0.1 ms
max. 2 analogue input channels
•
0.2 ms
max. 4 analogue input channels
•
0.5 ms
all 10 input channels
•
1.0 ms
for SMART sensors
Measured value memory
•
Single recording:
up to 500,000 measured values
•
Archive memory:
128 MB
(for min. 100 individual recordings)
PC link interfaces
•
USB port
•
Serial interface (RS 232)
For communication and evaluation using the HYDAC
HMGWIN 3000
or
CMWIN
software and using HSP log
Dimensions and weight
•
Dimensions:
246 x 174 x 58 mm
•
Weight:
1100 g
Operating and ambient conditions
•
Operating temperature: 0 ... 50 °C
•
Storage temperature: -20 ... 60 °C
•
Relative humidity:
0 ... 70%
Technical standards
•
EMC:
EN 61000-6-1/2/3/4
•
Safety:
EN 61010
•
Protection class:
IP 40
Supply voltage
•
12 … 30V DC