HMG 3010
Page 7
Edition 2013-03-26 - V04 R01
Part No.: 669855
2 About Your HMG 3010
2.1 Items supplied
•
HMG 3010
•
Power supply for 90 ... 230 V
•
User Manual
•
CD-ROM containing USB drivers and HMGWIN and CMWIN software
(software for analyzing measurement data and sensor communication)
in addition to other product information
•
USB connector cable
2.2 Power supply
The HMG 3010 has an internal NiMH battery. To charge the battery, simply connect the
power supply with the HMG 3010 (see HMG 3010 connections, Section 9). The battery is
fully charged after approx. 2 hours.
A direct current supply (12 ... 30 V DC) can be also connected be to the power input socket
to operate the HMG or charge the battery.
When connecting the power supply to the input socket make sure that +U
B
is applied to the
inner contact of the plug and 0 V to the outer contact. A JEITA RC 5320-5 plug, for example,
is suitable for this purpose and is available in most electrical/electronics shops.
3 Technical Safety
The individual components of the HMG 3010 portable data recorder and the assembled unit
are subject to strict quality assurance inspection and testing. Each HMG 3010 undergoes a
final test. This ensures that when supplied the unit is free of defects and complies with the
published specifications.
The series HMG 3010 portable data recorders are maintenance-free and work perfectly
when used under the conditions specified. If, however, you do encounter problems, please
contact your HYDAC representative. Incorrect installation or tampering with the unit shall
invalidate all warranty claims.
Compliance with European Standards
The HMG 3010 series portable data recorders have the CE mark and thus comply with all
current German regulatory requirements and European standards relating to the operation of
these units. This ensures compliance with the applicable directives relating to electromagnet-
ic compatibility and the safety provisions according to the low-voltage directive.
This product complies with the provisions of the following European directives:
EN 61000-6-1 / 2 / 3 / 4.
We reserve the right to make technical modifications.