6.5.1.2 Voltage supply ZBE 3010
Under the following conditions the CAN adapter
ZBE 3010 must have a separate voltage supply.
-
A
CAN
bus subscriber with a current
consumption of
≥
100 mA is directly connected.
-
The entire voltage for the connected bus system
is to be supplied via the ZBE 3010.
To supply voltage to the ZBE 3010 the HMG 3010
power supply (Part No.: 6054296) can be used.
Pin
Signal
Male
0 V (GND)
Female +18 V (+U
B
)
6.5.2 Main menu CAN bus
Navigate via
Settings
Change settings of measurement
channels
Channel D - CAN bus
to reach the main menu for CAN
functionality and to be able to adapt this to
your requirements.
If "Channel D CAN bus" is selected, the dis-
play jumps to the following window.
6.5.2.1 Sub-channel 01 .. Sub-channel 32
In this window you can activate and then
configure up to 32 CAN-messages (Sub-
channels). These messages are then evalu-
ated by the HMG like "normal" measurement
channels (measured values).
6.5.2.2 Configuring the message
When you have selected and activated a
message (sub-channel), the configuration
window will open, as shown on the right.