Installation and Maintenance Manual
31
Description of Functions Available in the Installer Menu
Installer 1
[uC 0]
Set UL Usage Class:
This menu item is used to set the UL usage class, which must be
set by the installer before the operator will function.
Installer 2
[bu 0]
Select Buzzer Type:
This menu item selects the type of audible buzzer installed on the
machine. To set, push SELECT on the keypad, the display will flash 0, push OPEN and note the buzzer
volume. Push OPEN again and note the buzzer volume. If this tone is louder, push SELECT, if the first tone
was louder, push CLOSE for the louder tone, then push SELECT to lock in the louder tone.
Installer 3
[Fd 0]
Load Factory Defaults:
This menu item is used to globally restore all menu settings
back to new machine status. To activate, change the setting 0 to 1 and push the Menu button. The UL usage
class and the hand configuration will need to be set again.
Installer 4
[dg 0]
Set Solo, Master or Slave type:
This menu item is used to configure an operator as a
Master or a Slave operator in Master/Slave paired gate installations.
Installer 5
[Ch 0]
Set AC Charger or Solar:
This menu item appears on 24 VDC battery machines only
and is set to solar only when there is no AC battery charger.
Installer 6
[Fo 0]
Enable Fire Dept. Open:
This menu item is used to enable the Fire Dept. Open input.
When set to [Fo_1] this input will override vehicle detectors, photo eyes and gate edges to open a gate. A
reset is required before the gate can be closed.
Installer 7
[oC 0]
Enable Emergency Close:
This menu item is used to enable the Emergency Close
input. When set to [oC_1] this input will override vehicle detectors, photo eyes and gate edges to close a
gate. A reset is required before the gate can be opened.
Installer 8
[SE 6]
Inherent Sensor sensitivity:
. This menu item is to adjust the sensitivity of the internal
inherent sensor. Available settings are 1-9, with 9 being the least sensitive.
Installer 9
[SS 0]
Inherent Sensor function:
This menu item is only available in UL class 4 operators and
allows an option whereby the inherent sensor will only stop the gate. (No reversal in either direction
–
overrides Installer 16.)
Installer 10
[LC 0]
Leaf delay Close:
This menu item only appears if the operator is set up as a Master or
a Slave. Available settings are 1-7. Each increment adds ½ second, to a maximum of 3 ½ seconds time
delay, before the operator activates when commanded to close.
Installer 11
[Lo 0]
Leaf delay Open:
This menu item only appears if the operator is set up as a Master or a
Slave. Available settings are 1-7. Each increment adds ½ second, to a maximum of 3 ½ seconds time delay,
before the operator activates when commanded to open.
Installer 12
[rt 0]
Maximum run timer:
The maximum run timer has a default setting of 60 seconds. This
menu item allows an optional setting of 300 seconds, if changed to [rt_1].
Installer 13
[EC 0]
PEC (photo eye close) reverse to open:
The default for this menu item is for non-
reversal if the close photo eye is triggered. The optional setting of [EC_1] will cause the gate to reverse to
open for two seconds if triggered while closing.
Installer 14
[EO 0]
PEO (photo eye open) reverse to close:
The default for this menu item is for non-
reversal if the open photo eye is triggered. The optional setting of [EO_1] will cause the gate to reverse to
close for two seconds if triggered while opening.
Installer 15
[gr 0]
Edge reverse to open:
The default for this menu item is for a 2 second reversal if the
gate edge is triggered. The optional setting of [gr_1] will cause the gate to reopen fully if triggered while
closing.
Summary of Contents for SwingRiser 14
Page 2: ......
Page 18: ...Installation and Maintenance Manual 8 Tools Required for an Efficient Installation ...
Page 19: ...Installation and Maintenance Manual 9 Swing Gate Post Details ...
Page 20: ...Installation and Maintenance Manual 10 Swing Gate Post Details continued ...
Page 21: ...Installation and Maintenance Manual 11 Swing Gate Post Details continued ...
Page 22: ...Installation and Maintenance Manual 12 HRG 220 Pump Pack ...
Page 23: ...Installation and Maintenance Manual 13 HRG 222 Pump Pack ...
Page 24: ...Installation and Maintenance Manual 14 How Our Hydraulic Swing Gates Work ...
Page 32: ...Installation and Maintenance Manual 22 ...
Page 54: ...Installation and Maintenance Manual 44 Loop Layouts ...
Page 77: ...Installation and Maintenance Manual 67 ...
Page 83: ...Installation and Maintenance Manual 73 Smart Touch Controller Connections ...