EZ
601211-10
22 IGNITION SYSTEM
Stator winding, measurement II - check the resistance
0
Measure the resistance between the specified points.
Stator, connector
EZ
pin 1 - Stator, connector
EZ
pin
3
Alternator
Resistance of stator
I
0.368 ... 0.552 Q
winding at: 20 °c (68 °F)
If the value displayed does not meet specifications:
-
Change the stator.
Stator winding - check for a short circuit to ground (terminal 31)
Measure the resistance between the specified points.
Stator, connector
EZ
pin
1
- Measuring point
Ground
(-)
I
Resistance
I
oo Q
If the value displayed does not meet specifications:
Change the stator.
22.4
Removing the stator
Condition
The alternator cover has been removed.
Remove screw
O
and take off the cable holder.
Remove cable support sleeve
8
from the alternator case.
Remove screws
fD.
Take the stator out of the alternator cover.