9 SHOCK ABSORBER, SWINGARM
70
Clamp the control lever as shown in the figure.
✓ The
External tank
fD
control lever is
on
Closed, Damper
C,
on Vacuum,
and
Oil reservoir
0
on Vacuum.
Operate the
On/Off
switch (D.
✓ The vacuum pump process starts.
✓ Pressure gauge @ drops to the specified value.
I < 0 bar
✓ The vacuum gauge fa) falls to the specified value.
14
mbar
Measure distance
f)
between the floating piston and reser
voir hole with the special tool.
I Depth micrometer (T107S) (
a
p. 321)
✓ The floating piston is positioned all the way at the bot
tom.
When the vacuum pressure gauge reaches the specified
value, turn the
Oil reservoir
control lever
0
to
Equalize pressure.
Guideline
14
mbar
✓ The pressure gauge increases to the specified value.
0 bar
When the pressure gauge reaches the specified value, turn
the
Damper
control lever
C,
to Pressure.
Guideline
0 bar
✓ Oil is pumped into the damper.
✓ The pressure gauge increases to the specified value.
3 bar
When the pressure gauge reaches the specified value, turn
the
Damper
C,
control lever to
Vacuum.
Guideline
3 bar
✓ The pressure gauge drops to the specified value.
0 bar
Summary of Contents for FE 450 2014
Page 1: ...PIONEERING SINCE 1903 REPAIR MANUAL2014 FE 450 FE 501 Art no 3403003en Husqvarna MOTORCYCLES ...
Page 2: ......
Page 82: ...9 SHOCK ABSORBER SWINGARM 80 Remove the motorcycle from the lift stand p 12 ...
Page 263: ...28 SERVICE SCHEDULE 261 ...
Page 328: ...32 SPECIAL TOOLS Filling tool 2x 3x Art no T170S1 T170S1 H00855 01 326 ...
Page 336: ...INDEX Page 6 of 8 272 288 Page 7 of 8 274 290 Page 8 of 8 276 292 Work rules 8 334 ...