Hunter Engineering Company recommends using the inner and outer Dataset® arms
to enter dimensions.
Refer to “Using the Auto Dataset
®
Arms,” page 59.
Measuring Dimensions for Standard Clip-on Weight Balancing
To measure rim dimensions for clip-on weights, activate the Standard balancing
mode. Pull the inner Dataset® arm away from the weight tray and
UPWARD
until it
is touching the top of the wheel inner rim lip. Simultaneously pull the outer
Dataset® arm out and upward until it is touching the top of the wheel outer rim lip.
While the Dataset® arms are in place, depress the foot pedal to enter the
dimensional data. The
GSP9720JLR
will beep to confirm data entry.
NOTE:
Dataset® arms can input dimensions separately if desired.
Measuring Dimensions for Mixed Weights (Clip-on/Adhesive) Balance
To measure rim dimensions for the clip-on weight, pull the inner Dataset® arm
away from the weight tray and
UPWARD
until it is touching the wheel inner rim lip.
Depress the foot pedal to enter the dimensional data. The
GSP9720JLR
will beep
to confirm data entry.
Do
NOT
return the Dataset® arm to the home position.
Move the Dataset® arm
DOWNWARD
until the roller disk edge is touching the
wheel at the right edge of the desired adhesive weight location. Depress the foot
pedal to enter the dimensional data. The
GSP9720JLR
will beep to confirm data
entry.
60
x
Balancing Procedures
GSP9720JLR Wheel Balancer Operation Instructions
Summary of Contents for GSP9700 Series
Page 2: ......
Page 88: ...80 x Balancing Procedures GSP9720JLR Wheel Balancer Operation Instructions ...
Page 118: ...110 x Road Force Measurement Procedures GSP9720JLR Wheel Balancer Operation Instructions ...
Page 152: ...144 x Theory of Operation GSP9720JLR Wheel Balancer Operation Instructions ...