![Hunter GSP9700 Series Operation Instructions Manual Download Page 134](http://html1.mh-extra.com/html/hunter/gsp9700-series/gsp9700-series_operation-instructions-manual_2186597134.webp)
Place the outer Dataset® arm at position “1.” Tap the foot pedal once or press “Enter
Cal Step.”
NOTE:
If the outer Dataset® arm is unstable while entering any
step, a long, high-pitched tone will sound to advise that the
step has NOT been entered. Stabilize the arm and re-enter
the step.
Place the outer Dataset® arm at position “2.” Tap the foot pedal once or press “Enter
Cal Step.”
Place the outer Dataset® arm at position “3.” Tap the foot pedal once or press “Enter
Cal Step.”
Loosen the outer Dataset® arm locking screw by turning it counterclockwise and
rotate the outer arm ball into the downward position by pulling the locator pin out of
the locator slot and rotating the ball 180 degrees. Secure the locking screw. Place
the calibration tool on the hub using the hub mounting slot as shown.
Place the outer Dataset® arm ball in the hole for position “4.” Tap the foot pedal once
or press “Enter Cal Step.”
Place the outer Dataset® arm at position “5.” Tap the foot pedal once or press “Enter
Cal Step.”
Place the outer Dataset® arm at position “6.” Tap the foot pedal once or press “Enter
Cal Step.”
Rotate the outer arm ball back to the upward position.
Outer Dataset® arm calibration is complete.
Load Roller (Calibration Tool, 221-672-1, Required)
Select “Load Roller” from the “Calibration Procedures” primary screen.
Select “Begin Procedure.”
126
x
Calibration and Maintenance
GSP9720JLR Wheel Balancer Operation Instructions
Summary of Contents for GSP9700 Series
Page 2: ......
Page 88: ...80 x Balancing Procedures GSP9720JLR Wheel Balancer Operation Instructions ...
Page 118: ...110 x Road Force Measurement Procedures GSP9720JLR Wheel Balancer Operation Instructions ...
Page 152: ...144 x Theory of Operation GSP9720JLR Wheel Balancer Operation Instructions ...