Place the inner Dataset® arm at upward position “1.” Tap the foot pedal once or
press “Enter Cal Step.”
NOTE:
If the inner Dataset® arm is unstable while entering any
step, a long, high-pitched tone will sound to advise that the
step has
NOT
been entered. Stabilize the arm and re-enter
the step.
Place the inner Dataset® arm at upward position “2.” Tap the foot pedal once or
press “Enter Cal Step.”
Place the inner Dataset® arm at upward position “3.” Tap the foot pedal once or
press “Enter Cal Step.”
GSP9720JLR Wheel Balancer Operation Instructions
Calibration and Maintenance
x
123