HZ-C Path Instrument
I. Function
It provides 15KHZ high frequency signal and 300HZ audio signal power output.
It can perform measuring cable path, buried depths, short circuit fault point with the
location instrument.
II. Technical Parameters
⑴
Power: 220V AC 80W
⑵
Output power: 15 kHz high-frequency, no less than 50W.
300 Hz low-frequency, no less than 70W.
⑶
Waveform selection: Continuous or intermittent.
⑷
Output voltage: Fourth gear of 0-10V, 0-25V, 0-50V, 0-100V
Output Current: 0-1000mA
⑸
Output frequency: 15 kHz (for path detection)
300Hz (for electromagnetic location)
⑹
Exo: 105(high)
╳
240(width)
╳
290(Depth) mm
III. Usage
①
Connected to power, and then turn on the switch. In this case, the screen displays
the output current as 000.
②
Select frequency according to the nature of the work (such as 15KHz frequency for
detection path, 300Hz Audio for electromagnetic wave location). Press "Frequency",
and the frequency selected will be displayed on the screen. Then select waveform
according to your listening habits. Press "waveform" key, and "continuous" or
"intermittent" selected will be displayed on the screen.