III. Technical Indicators
1 Test methods: Arc reflection method, current sampling, and DC output.
2 Types of sampling signals: Arc reflection method, current sampling, and
low-voltage pulse.
3 DC voltage output:
0 ~ 32kV Negative
Maximum output current: 76mA
0 ~ 16kV Negative
Maximum output current: 152mA
4 Impact capacitor:
0 ~ 32kV 3μF Maximum output energy: 1536 joules
0 ~ 16kV 12μF Maximum output energy: 1536 joules
5 Ball-gap discharge: Weak electricity control. Discharge cycle can be adjusted within
3-12 seconds. It has a specially designed silencer, which meets the requirement of
silence when fault happened to the initial end cable.
6 Protection:
Zero voltage position protection: To prevent misuse, and to protect the safety of
personal and the test product;
Press "off" button, and it will release the remaining charge automatically through
safety instrument inside to ensure safety.
7 It is equipped with extension cable tray, which can be composed of automotive
cable fault location system.