Follow-up Procedure
Verify the following after the installation:
l
The labels at both ends of the cable are correct, clear, neat, and facing the same direction.
l
The cables and connectors are free of any damage or breakage and are connected
properly and reliably.
3.2.8 Connecting a Power Adapter
USG6305/6305-W/6310S/6310S-W/6310S-WL-OVS/6510/6510-WL provides a 24W power
supply adapter, which can be directly connected to the power supply in the equipment room
without requiring an AC power cable.
Context
Before connecting a power connector, ensure that the power source of the equipment room
meets the input requirements of the USG power module.
Procedure
Step 1
Ensure that the PGND cable is properly grounded.
Step 2
Insert a cable-retention clip into the jack next to the power socket.
Step 3
Connect a power adapter.
1.
Insert the 4-PIN connector of the power adapter into the power socket on the USG rear
panel and adjust the cable-retention clip to an appropriate position.
2.
Use a cable-retention clip to bundle the cable of the power adapter and adjust the cable-
retention clip to fasten the cable.
3.
Plug the other end of the power adapter to the AC power socket or the output of the AC
power supply device.
NOTE
The USG does not have any power switch. The power supply switch determines the power-on and
power-off of the USG.
HUAWEI USG6000 Series
Hardware Guide
3 Hardware Installation
Issue 08 (2017-06-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
267