l
The power switch in the equipment room is easy to locate so that you can power off
devices in the case of accidents.
Procedure
l
Power on the USG.
Turn on the switch of the power supply device and then the switch on the power module
of the USG. The USG starts.
You can identify the USG status based on indicators on the front and rear panels.
Indicators shown in
indicate that the USG runs normally.
Figure 3-54
Indicators when the
USG6306/6308/6330/6350/6360/6370/6380/6390/6390E/
6507/6530/6550/6570/6620/6630 runs normally
Secospace USG6000
4 HDD
5 PWR 6 PWR
INPUT
OUTPUT
ON
OFF
~100-240V;50/60Hz;2.5A
XXXXXXXXXXXXXXXXXXXXXXXXXXX
SM-HDD-SAS300G-B
Secospace USG6000
0
1
2
3
4
5
6
7
8
9
10
11
0
1
RST
SYS
ALM
PWR
HDD
MGMT
MODE
0/1
2
3
CONSOLE
MGMT
NPUT: steady green
OUTPUT: steady green
INPUT
OUTPUT
ON
OFF ~100-240V;50/60Hz;2.5A
Front view
Rear view
SYS
ALM
PWR
HDD
MGMT
MODE
SYS: blinking green (once every two seconds)
ALM: off
PWR: steady green
Alarm indicator: off
RUN indicator: blinking green
SM-HDD-SAS300G-B
l
Power off the USG.
HUAWEI USG6000 Series
Hardware Guide
3 Hardware Installation
Issue 08 (2017-06-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
306