Step 3
Wait for one minute and run the
reset raid
primary-disk
disk-id
command in the system
view to create a RAID group using
disk-id
as the primary disk for data synchronization.
Step 4
Wait for 4 to 5 hours, run the
display disk information
command, check whether
Filesystem
Status
is
Mounted
and
DiskCapacity_Total
is a large capacity. If yes, capacity expansion
succeeds, and the hard disks are working properly.
NOTE
Filesystem Status
becomes
Mounted
four to five hours after the
reset raid
command is run. During
this period, you can use other services, but the hard disks do not record real-time logs for these services.
After data synchronization completes, the hard disks automatically start to work. You can run the
display disk information
command in the user view on the next day to check whether
Filesystem
Status
is
Mounted
. If not, contact Huawei technical support personnel.
----End
4.4 Replacing a Power Module
This section describes how to replace a faulty power module.
Context
Required tools:
l
Phillips screwdriver
When two power modules are installed on the USG, one of them is hot swappable. Pay
attention to the following items during hot swapping:
HUAWEI USG6000 Series
Hardware Guide
4 Maintaining the Hardware
Issue 08 (2017-06-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.