background image

 

 

Description of Issue  

 
Due to an incorrect partition of the flash storage device, the FortiGate 80C may fail to boot-up. The 
flash disk capacity should be 

7640MB

 in size, devices that report a flash disk size of 

7636MB

 have a 

hidden partition 

(4MB)

 which may prevent the FortiGate from booting up if it attempts to locate the 

operating system image in this partition.  
 
The FortiGate models that may be affected by this issue are as follows:  
  
FG-80C      (PN: P05403-05-xx or higher)  
FG-80CM   (PN: P05446-05-xx or higher)  
FW-80CM   (PN: P05405-06-xx or higher)  
  
To identify the part number (PN) of a specific unit, either;  
1)  Check the label on the bottom of the unit  
or  
2)  Use the “get system status” command from the CLI  
  
The part number of a device can be identified using the following CLI command:  
  

FGT80C3900000000 # get system status   
*************  
Serial-Number: FGT80C3900000000  
*************  

System Part-Number: P05403-05  

  
If your FortiGate is within the affected part number range you can verify the flash disk size to know if 
it is correct or if there is a hidden partition that may cause the device to fail to boot-up. Upon boot-
up the flash size may be reported  
  

Boot up, boot device capacity: 4MB      ---  Incorrect, the device will not boot  
Boot up, boot device capacity: 7636MB   ---  Incorrect  
Boot up, boot device capacity: 7640MB   ---  Correct  

  
 
 
 
 
 