Tecal RH5485 Server
Problem Determination and Service Guide
3 Diagnostics
Issue 02 (2011-05-25)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3-79
Message
Severity Description
Action
Sensor PS n 12V OV
Fault has transitioned to
non-critical from a nor- mal
state.
(n = power supply number)
Warning A sensor has changed
tonon-critical state from a normal
state
1. Check the OVER SPEC
LED (see the information about
the OVER SPEC LED in “Light
path diagnostics LEDs”).
2. Remove the power
supplies.
3. Replace power supply
n
.
4. (Trained service technician
only) Replace the I/O-board
shuttle.
(
n
= power supply number)
Sensor PS n 12V UV
Fault has transitioned to
non-critical from a nor- mal
state.
Warning A sensor has changed
tonon-critical state from a normal
state
1. Check the OVER SPEC
LED (see the information about
the OVER SPEC LED in “Light
path diagnostics LEDs”).
2. Remove the power supplies.
3. Replace power supply n.
4. (Trained service technician
only) Replace the I/O-board
shuttle.
(n = power supply number)
Sensor PS n 12V OC
Fault has transitioned to
non-critical from a nor- mal
state..
(n = power supply number)
Warning A sensor has changed
tonon-critical state from a normal
state
1. Check the OVER SPEC
LED (see the information about
the OVER SPEC LED in “Light
path diagnostics LEDs” ).
2. Remove the power
supplies.
3. Replace power supply
n
.
4. (Trained service technician
only) Replace the I/O-board
shuttle.
(
n
= power supply number)
Sensor PS n CSF
Fault has transitioned to
a non-critical state from
a normal state.
(n = power supply number)
Warning A sensor has changed
tonon-critical state from a normal
state
1. Check the power supply n
LEDs.
2. Replace the failing power
supply.
(n = power supply number)