3 Diagnostics
Tecal RH5485 Server
Problem Determination and Service Guide
3-24
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 02 (2011-05-25)
microprocessor 2 in the microprocessor 1
connector. Restart the server. If the error is
corrected, microprocessor 1 is bad and
must be replaced. Repeat this step for
microprocessors 2, 3, and 4 if necessary.
4.
Replace the following components one at
a time, in the order shown, restarting the
server each time:
a)
(Trained service technician only)
Microprocessor 1
b)
(Trained service technician only)
Microprocessors 2, 3, and 4
c)
(Trained service technician only)
Microprocessor board
Invalid microprocessor type
1.
Update the firmware (see “Updating the
firmware”).
2.
(Trained service technician only) Remove
and replace the affected microprocessor
(error LED is lit) with a supported type.
Microprocessor mismatch
1.
Run the Setup utility and view the
microprocessor information to compare
the
installed
microprocessor
specifications.
2.
(Trained service technician only) Remove
and replace one of the microprocessors so
that they both match.
0011004
Microprocessor
failed
built-in self-test (BIST)
1. Update the firmware (see “Updating the
firmware”).
2. (Trained service technician only) Reseat
microprocessor 2.
3. Replace the following components one at a
time, in the order shown, restarting the server
each time:
a.
(Trained
service
technician
only)
Microprocessor
b.
(Trained
service
technician
only)
Microprocessor board
001100A
Microcode update failed
1. Update the server firmware (see “Updating
the
firmware” ).
2. (Trained service technician only) Replace
the
microprocessor.