3 Diagnostics
Tecal RH5485 Server
Problem Determination and Service Guide
3-74
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 02 (2011-05-25)
Message
Severity Description
Action
A Uncorrectable Bus
Error has occurred on
system %1.
(
%1 = CIM_ComputerSystem
.ElementName
)
Error
A bus uncorrectable error has
occurred.
(Sensor = Critical Int CPU)
1. Check the system-event log.
2. Check the microprocessor
error LEDs.
3. Remove the failing
microprocessor from the
microprocessor board.
4. Check for a server firmware
update.
Important: Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify that
the latest level of code is
supported for the cluster solution
before you update
the code.
5. Make sure that all of the
installed microprocessors are
matching.
6. (Trained service technician
only) Replace the microprocessor
board.
A Uncorrectable Bus
Error has occurred on
system %1.
(
%1 = CIM_ComputerSystem
.ElementName
)
Error
A bus uncorrectable error has
occurred.
(Sensor = Critical Int DIMM)
1. Check the system-event log.
2. Check the DIMM error
LEDs.
3. Remove the failing DIMM
from the memory board.
4. Check for a server firmware
update.
Important
: Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify that
the latest level of code is
supported for the cluster solution
before you update
the code.
5. Make sure that the installed
DIMMs are supported and
configured correctly.
6. (Trained service technician
only) Replace the failing memory
card.