Tecal RH5485 Server
Problem Determination and Service Guide
3 Diagnostics
Issue 02 (2011-05-25)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3-67
Numeric sensor Planar 12V
going low
(lower critical) has
deasserted.
Info
A lower critical sensor going low
has deasserted.
No action; information only.
Numeric sensor Planar 12V
going high (upper critical)
has deasserted.
Info
An upper critical sensor going
high has deasserted.
No action; information only.
Numeric sensor Planar
VBAT going low (lower
non-critical) has deasserted.
Warning A lower non-critical sensor going
low as asserted.
No action; warning that the
battery might be going bad.
Numeric sensor Planar
VBAT going low (lower
critical) has asserted.
Error
A lower critical sensor going low
has asserted.
Replace the 3 V battery.
Numeric sensor Planar
VBAT gong low (lower
non-critical) has deasserted.
Info
A lower non-critical sensor going
low has deasserted.
No action; information only.
Numeric sensor Planar
VBAT going low (lower
critical has deasserted.
Info
A lower critical sensor going low
has deasserted.
No action; information only.
Numeric sensor FannTach
(n = fan number)
Error
A lower critical sensor going low
has deasserted.
1. Reseat the failing fan x,
which is indicated by the lit LED
near the fan connector on the
microprocessor board.
2. Replace the failing fan.
(x = fan number)
Numeric sensor Fan nA
Tach going low (lower
critical) has asserted.
(n = fan number)
Error
A lower critical sensor going low
has asserted.
1. Reseat the failing fan n,
which is indicated by a lit LED
near the fan connector on the
microprocessor board.
2. Replace the failing fan.
(n = fan number)
Numeric sensor Fan n B
Tach going low (lower
critical) has asserted.
(n = fan number)
Error
A lower critical sensor going low
has asserted.
1. Reseat the failing fan n,
which is indicated by a lit LED
near the fan connector on the
microprocessor board.
2. Replace the failing fan.
(n = fan number)
Numeric sensor Fan n
Tach going low (lower
critical) has deasserted.
Info
A lower critical sensor going low
has deasserted.
No action; information only.
Numeric sensor Fan n
Tach going low (lower
critical) has deasserted.
Info
A lower critical sensor going low
has deasserted.
No action; information only.