Table 5-6 Configuration process
Step
Action
Set the
management
network port IP
address.
Set an IP address for the management network port.
Log in to the iBMC
WebUI.
Log in to the iBMC WebUI from a local PC.
Check the server.
● Check that the server version information is correct.
● Check that no alarm is generated for the server.
Change the initial
passwords.
● Change the iBMC user name and password for the
server.
● Change the U-boot password.
Configure RAID.
Configure RAID for the server. For details, see the
Controller Card User Guide (Kunpeng Processors)
Configure the
BIOS.
Configure the server BIOS, including setting the boot
option priority and BIOS password.
Install an OS.
Install an OS for the server.
5.11.3 Querying the iBMC IP Address
Scenario
Query the IP address of the iBMC on the server using the BIOS.
Default IP Address
The default IP address of the iBMC management network port is 192.168.2.100.
Procedure
Step 1 Access the BIOS. For details, see
.
Step 2 Choose Advanced > IPMI iBMC Configuration > iBMC Configuration, and press
Enter.
The iBMC Config screen is displayed. See
TaiShan 200 Server (Model 2280)
User Guide
5 Installation and Configuration
Issue 09 (2021-01-12)
Copyright © Huawei Technologies Co., Ltd.
67