A.6 Sensor List (Server Configured with the Kunpeng
920 5220 or 3210 Processor)
Sensor
Description
Component
Inlet Temp
Air inlet temperature
Right mounting ear
Outlet Temp
Air outlet temperature
iBMC card
CPU
N
Core Rem
CPU core temperature
CPU.
N
indicates the CPU
number. The value is 1 or 2.
CPU
N
Prochot
CPU Prochot
CPU
N
VDDQ Temp
CPU VDDQ temperature
CPU 1: Components in
positions U1 on the
mainboard.
CPU 2: Components in
positions U2 on the
mainboard.
N
indicates the CPU number.
The value is 1 or 2.
CPU
N
VRD Temp
CPU VRD temperature
CPU 1: Components in
positions U1 on the
mainboard.
CPU 2: Components in
positions U2 on the
mainboard.
N
indicates the CPU number.
The value is 1 or 2.
CPU
N
MEM Temp
CPU DIMM temperature
DIMMs of CPU
N
.
N
indicates
the CPU number. The value is
1 or 2.
Disks Temp
Highest temperature
among the temperature
of all drives
-
FAN
N
Speed
Fan speed sensor
Fan module.
N
indicates the
fan module number. The
value ranges from 1 to 4.
Power
Server input power
Total PSU power
Power
N
PSU input power
PSU.
N
indicates the PSU
number. The value is 1 or 2.
CPU
N
Status
CPU status
CPU.
N
indicates the CPU
number. The value is 1 or 2.
TaiShan 200 Server (Model 2280)
User Guide
A Appendix
Issue 09 (2021-01-12)
Copyright © Huawei Technologies Co., Ltd.
180