Item
Description
Ground cable
The 2280 does not provide a separate ground port. It is
grounded through the ground cable of a power cable. Ensure
that the power cables of the PSUs are in good contact.
5.9 Powering On the Server
Power on the server using one of the following methods based on the actual
situation:
●
If the PSUs are properly installed but are not connected to an external power
supply:
Connect the external power supply to the PSUs. Then the server will power on
with the PSUs.
NO TE
The default value of System State Upon Power Supply is Power on, which indicates
that the server automatically powers on after power is supplied to the PSUs. To
change the value of System State Upon Power Supply, log in to the iBMC WebUI and
choose Power > Power Control.
●
If the PSUs are properly installed and connected to the external power supply
and the server is in the standby state (the power indicator is steady yellow),
power on the server as follows:
–
Press the power button on the front panel to power on the server. For
details about the power button position, see
–
Power on the server using the iBMC WebUI.
i.
Log in to the iBMC WebUI. For details, see
5.12.4 Logging In to the iBMC WebUI
ii. Open the Power Control page.
○
For iBMC V549 or earlier, choose Power > Power Control.
○
For iBMC V561 and V3.01.00.00 or later, choose System > Power
> Power Control.
iii. Click Power On. In the displayed dialog box, click Yes to power on
the server.
–
Power on the server using the Remote Virtual Console.
i.
Log in to the Remote Virtual Console. For details, see
In to the Remote Virtual Console through the iBMC WebUI
9.2.1 Logging In to the Remote Virtual Console through the iBMC
.
ii. On the KVM screen, click or
on the menu bar.
iii. Choose Power On.
A dialog box is displayed.
iv. Click Yes to power on the server.
TaiShan 200 Server (Model 2280)
User Guide
5 Installation and Configuration
Issue 09 (2021-01-12)
Copyright © Huawei Technologies Co., Ltd.
63