Table 3-3 Operating temperature limitations
Model
Max. 30°C
(86°F)
Max. 35°C (95°F)
(ASHRAE Class A2
Compliant)
Max. 40°C (104°F)
(ASHRAE Class A3
Compliant)
12 x 3.5"
drive EXP
configuratio
n
Supports all
options.
Supports all
options.
Options not supported:
● 64-core CPUs
● PCIe SSD cards
● Passive GPU cards
(including DMINI
cards)
● Rear drives
● Kunpeng 920 7265 or
5255 processors
12 x 3.5"
drive pass-
through
configuratio
n
25 x 2.5"
drive EXP
configuratio
n
24 x 2.5"
drive pass-
through
configuratio
n
8 x 2.5" SAS/
SATA + 12 x
2.5" NVMe
drive
configuratio
n
Supports all
options.
Supports all
options.
Not supported
8 x 2.5"
drive
configuratio
n
Supports all
options.
Supports all
options.
Kunpeng 920 7265 or
5255 processors are not
supported.
NOTE
● If one fan fails, the highest operating temperature of the server is 5°C (9°F) lower than
that in normal cases.
● When powered by Kunpeng 920 5220 or 3210 processors, the server does not support
24 x 2.5" SAS/SATA pass-through drive configuration or 8 x 2.5" drive configuration.