Command Manual - Network Protocol
Quidway S6500 Series Ethernet Switches
Chapter 2 ARP Configuration Commands
Huawei Technologies Proprietary
2-3
View
System view
Parameter
aging-time
: Aging time of dynamic ARP aging timer, which is in the range of 1 to 1440
minutes. By default, the aging time is 20 minutes.
Description
Using
arp timer aging
command, you can configure the dynamic ARP aging timer.
Using
undo arp timer aging
command, you can restore the default dynamic ARP
aging time.
For the related command, see
display arp timer aging
.
Example
# Configure the dynamic ARP aging timer to 10 minutes.
[Quidway] arp timer aging 10
2.1.4 debugging arp
Syntax
debugging arp
packet
undo debugging arp
packet
View
User view
Parameter
packet
: ARP packet debugging.
Description
Using
debugging arp
command, you can enable ARP debugging. Using
undo
debugging arp
command, you can disable the corresponding ARP debugging.
By default, undo ARP debugging is enabled.
For the related command, see
arp static
,
display arp
.
Example
# Enable ARP packet debugging.
<Quidway> debugging arp packet
*Aug 31 10:30:20 2005 C_0.6506r ARP/8/arp_send:Send an ARP Packet, operation :
1