Command Manual - Port
Quidway S6500 Series Ethernet Switches
Chapter 1 Ethernet Port Configuration Commands
Huawei Technologies Proprietary
1-9
Description
Using
flow-control
command, you can enable flow control feature on the Ethernet port
to avoid discarding data packets due to congestion. Using
undo flow-control
command, you can disable flow control feature.
By default, flow control on the Ethernet port is disabled.
Example
# Enable flow control on Ethernet1/0/1.
[Quidway-Ethernet1/0/1] flow-control
1.1.9 interface
Syntax
interface
{
interface_type interface_num | interface_name
}
View
System view
Parameter
interface-type
: Specifies the port type. it can be Ethernet or GigabitEthernet or
M-Ethernet.
interface_num
: Specifies the port number. The port number can be expressed as
slot-number
/
subslot-number
/
port-number
. For S6506 and S6506R Ethernet Switches,
slot-number
specifies the LPU slot number of the port. For S6506, it ranges from 1 to 6.
For S6506R, it ranges from 2 to 7.
subslot-number
specifies the sub-slot number of the
port. For the slot without subslot, the subslot-number is fixed as 0. For the slot with
subslot, the subslot-number ranges from 1 to 4, according to how many ports a subslot
provides.
port-number
specifies the port number on the LPU and ranges from 1 to 8, 24,
or 48 according to how many ports a LPU provides. For S6503 Ethernet Switch, the
LPU slot-number ranges from 1 to 3 and SRPU slot-number ranges from 0 to 3.
Subslot-number takes 0 or ranges from 1 to 4, and the port number ranges from 1 to 8,
24, or 48. M-Ethernet is used to update and maintain. It ranges from 0/0/0.
interface_name
: Specifies the port name in the
interface_name
=
interface_type
interface_num
format.
Description
Using
interface
command, you can enter the Ethernet port view.
If the user wants to configure the related parameters of the Ethernet port, he must first
use this command to enter the Ethernet port view.