![Huawei Quidway S5600 Operation Manual Download Page 980](http://html.mh-extra.com/html/huawei/quidway-s5600/quidway-s5600_operation-manual_169841980.webp)
Operation Manual - HWPing
Quidway S5600 Series Ethernet Switches-Release 1510
Chapter 1 HWPing Configurations
Huawei Technologies Proprietary
1-3
Operation
Command
Description
Configure the
timeout time of the
test.
timeout
time
Optional
By default, the timeout
time is 3 seconds.
Execute the test
test-enable
Required
1.2.3 Displaying HWPing Configuration
After the above HWPing configurations, you can execute the
display
command in any
view to display the information of operation status through which you can verify the
configuration effect.
Table 1-2
Display HWPing configuration
Operation
Command
Description
Display the information of
HWPing test history
display hwping history
[
administrator-name
operation-tag
]
Display the latest HWPing
test results
display hwping results
[
administrator-name
operation-tag
]
The
display
command
can be executed in any
view.
1.2.4 Configuration Example
I. Network Requirement
Perform an HWPing ICMP test between two switches. Like a ping test, this test uses
ICMP to test the RTTs of data packets between the source and the destination.
II. Configuration procedure
# Enable HWPing Client.
<Quidway> system-view
System View: return to User View with Ctrl+Z.
[Quidway] hwping-agent enable
# Create an HWPing test group “administrator icmp”.
[Quidway] hwping administrator icmp
# Specify the test type as ICMP.
[Quidway-hwping-administrator-icmp] test-type icmp
# Specify the destination IP address as 1.1.1.99.
[Quidway-hwping-administrator-icmp] destination-ip 1.1.1.99