Operation Manual – System Maintenance and Debugging
Quidway S5600 Series Ethernet Switches-Release 1510
Chapter 4 Device Management
Huawei Technologies Proprietary
4-2
Note:
When rebooting, the system checks whether there is any configuration change. If there
is, it prompts you to indicate whether or not to proceed. This prevents you from losing
your original configuration due to oblivion after system reboot.
4.2.3 Scheduling a Reboot on the Switch
After you schedule a reboot on the switch, the switch will reboot at the specified time.
Table 4-3
Schedule a reboot on the switch
Operation
Command
Description
Schedule a reboot
on the switch, and
set the reboot date
and time
schedule reboot at
hh:mm
[ mm/dd/yyyy | yyyy/mm/dd ]
Optional
Schedule a reboot
on the switch, and
set the reboot
waiting delay
schedule reboot delay
{
hh:mm
|
mm
}
Optional
Enter system view
system-view
—
Schedule a reboot
on the switch, and
set the reboot
period
schedule reboot regularity at
hh:mm
period
Optional
Note:
There is at most one minute defer for scheduled reboot, that is, the switch will reboot
within one minute after reaching the specified reboot date and time.
4.2.4 Specifying the APP to be Adopted at Reboot
APP is the host software of the switch. If multiple APPs exist in the Flash memory, you
can use the command here to specify the one that will be adopted when the switch
reboots.
Perform the following configuration in user view: