![Huawei Quidway S5600 Operation Manual Download Page 211](http://html.mh-extra.com/html/huawei/quidway-s5600/quidway-s5600_operation-manual_169841211.webp)
Operation Manual - DLDP
Quidway S5600 Series Ethernet Switches-Release 1510
Chapter 1 DLDP Configuration
Huawei Technologies Proprietary
1-8
Operation
Command
Description
Set the DLDP operating mode
dldp work-mode
{
enhance
|
normal
}
Optional
By default,
DLDP works in
normal mode
and does not
identify
unidirectional
links
Enter Ethernet port view
interface
interface-type
interface-number
-
Force the duplex attribute
duplex full
Required
Force the speed value
speed
speed-value
Required
Display the configuration
information about the
DLDP-enabled ports
display dldp
{
unit-id
|
interface-type
interface-number
}
You can
execute this
command in
any view.
Note:
z
When you use the
dldp enable/dldp disable
command in system view to
enable/disable DLDP globally on all optical ports of the switch, this command is only
valid for existing optical ports on the device, however, it is not valid for those added
subsequently.
z
DLDP can operate normally only when the same authentication mode and
password are set for local and peer ports.
z
When the DLDP protocol works in normal mode, the system can identify only one
type of unidirectional links: cross-connected fibers.
z
When the DLDP protocol works in enhanced mode, the system can identify two
types of unidirectional links: the first type is the cross-connected fiber, and the
second type is the fiber which is not connected or the fiber which is disconnected.
z
When the device is busy with services and the CPU utilization is high, DLDP may
issue mistaken reports. You are recommended to configure the operating mode of
DLDP as manual after unidirectional links are discovered, so as to reduce the
influence of DLDP mistaken reports.
1.2.2 Resetting DLDP Status