![Huawei Quidway S5600 Operation Manual Download Page 799](http://html.mh-extra.com/html/huawei/quidway-s5600/quidway-s5600_operation-manual_169841799.webp)
Operation Manual – PoE & PoE Profile
Quidway S5600 Series Ethernet Switches-Release 1510
Chapter 1 PoE Configuration
Huawei Technologies Proprietary
1-7
Note:
z
The
refresh
update mode is to upgrade the valid software in the PSE through
refreshing the software, while the
full
update mode is to delete the invalid software
in PSE completely and then reload the software.
z
Generally, the
refresh
update mode is used to upgrade the PSE processing
software.
z
When the PSE processing software is damaged (that is, all the PoE commands
cannot be successfully executed), you can use the
full
update mode to upgrade and
restore the software.
z
When the upgrading procedure in
refresh
update mode is interrupted for some
unexpected reason (such as power-off) or some errors occur, if the upgrade in
full
mode fails after restart, you must upgrade in
full
mode after power-off and restart of
the device, and then restart the device manually. In this way, the former PoE
configuration is restored.
1.10 Displaying PoE Configuration
After the above configuration, execute the
display
command in any view to see the
operation of the PoE feature and verify the effect of the configuration.
Table 1-9
PoE information display
Operation
Command
Description
Display the PoE
status of a specific
port or all ports of the
switch
display poe interface
[
interface-name
|
interface-type
interface-num
]
Display the PoE
power information of
a specific port or all
ports of the switch
display poe interface
power
[
interface-name
|
interface-type
interface-num
]
Display the PSE
parameters
display poe powersupply
Display the
enabled/disabled
status of the PoE
over-temperature
protection feature on
the switch
display poe
temperature-protection
You can execute the
display
command in
any view