1.2.7 Enabling Information Output to the SNMP
Table 1-12 lists the related configurations on the switch.
Table 1-12
Enable information output to the SNMP
Operation
Command
Description
Enter system view
system-view
—
Enable the
information center
info-center enable
Optional
By default, the information
center is enabled.
Enable information
output to the
SNMP
info-center snmp channel
{
channel
-
number |
channel
-
name
}
Required
By default, SNMP information
goes through channel 5.
Define an
information source
info
-
center source
{
modu
-
name
|
default
}
channel
{
channel
-
number |
channel
-
name
} [ {
log
|
trap
|
debug
} * {
level
severity
|
state
state
} * ]
Required
Set the format of
time stamp
info-center timestamp
{
log
|
trap
|
debugging
}
{
boot
|
date
|
none
}
Optional
This is to set the time stamp
format for log/debug/trap
information output.
This determines how the time
stamp is presented to users.
Note:
z
To view debug information of specific modules, you need to set the information type
as
debug
in the
info-center source
command, and enable debugging on
corresponding modules with the
debugging
command as well.
z
To send information to remote SNMP workstation properly, related configurations
are required on both the switch and the SNMP workstation.
1.3 Displaying and Debugging Information Center
After the above configurations, you can execute the
display
command in any view to
display the running status of the information center, and thus validate you
configurations. You can also execute the