Operation Manual – Login
Quidway S3100 Series Ethernet Switches
Chapter 2 Logging in through the Console Port
Huawei Technologies Proprietary
2-12
[Quidway-ui-aux0] set authentication password simple 123456
# Specify commands of level 2 are available to users logging into the AUX user
interface.
[Quidway-ui-aux0] user privilege level 2
# Set the baud rate of the Console port to 19,200 bps.
[Quidway-ui-aux0] speed 19200
# Set the maximum number of lines the screen can contain to 30.
[Quidway-ui-aux0] screen-length 30
# Set the maximum number of commands the history command buffer can store to 20.
[Quidway-ui-aux0] history-command max-size 20
# Set the timeout time of the AUX user interface to 6 minutes.
[Quidway-ui-aux0] idle-timeout 6
2.6 Console Port Login Configuration with Authentication
Mode Being Scheme
2.6.1 Configuration Procedure
Table 2-8
Console port login configuration with the authentication mode being scheme
Operation
Command
Description
Enter system view
system-view
—
Enter the
default ISP
domain
view
domain
system
Specify the
AAA
scheme to
be applied
to the
omain
d
scheme
{
local
|
radius-scheme
radius-scheme-name
[
local
] |
none
}
Configu
re the
authenti
cation
mode
Quit to
system
view
quit
Optional
By default, the local AAA
scheme is applied. If you specify
to apply the local AAA scheme,
you need to perform the
configuration concerning local
user as well.
If you specify to apply an
existing scheme by providing
the
radius
-
scheme-name
argument, you need to perform
the following configuration as
well:
z
Perform AAA&RADIUS
configuration on the switch.
(Refer to the AAA&RADIUS
module for more.)
z
Configure the user name and
password accordingly on the
AAA server. (Refer to the
user manual of AAA server.)