Operation Manual – Login
Quidway S3100 Series Ethernet Switches
Chapter 2 Logging in through the Console Port
Huawei Technologies Proprietary
2-14
Operation
Command
Description
Set the maximum
number of lines the
screen can contain
screen-length
screen-length
Optional
By default, the screen can
contain up to 24 lines.
You can use the
screen-length
0 command to disable the
function to display information in
pages.
Set history command
buffer size
history-command
max-size value
Optional
The default history command
buffer size is 10. That is, a
history command buffer can
store up to 10 commands by
default.
Set the timeout time for
the user interface
idle-timeout minutes
[
seconds
]
Optional
The default timeout time of a
user interface is 10 minutes.
With the timeout time being 10
minutes, the connection to a
user interface is terminated if no
operation is performed in the
user interface within 10 minutes.
You can use the
idle-timeout
0
command to disable the timeout
function.
Note that the level the commands of which are available to users logging into a switch
depends on the
authentication-mode
{
password
|
scheme
|
none
} command, the
user privilege level
level
command, and the
service-type
terminal
[
level level
]
command, as listed in Table 2-9.