Parameter
Description
Value
Interval
Time spent waiting of the two
synchronization methods,
Timed wait
when synchronization begins
and
Timed
wait when synchronization ends
.
NOTE
This parameter is available when
Replication
Mode
is set to
Asynchronous
and
Synchronization Method
is set to
Timed wait
when synchronization begins
or
Timed wait
when synchronization ends
.
[Value range]
–
The interval is
an integer
ranging from 1
to 1440
(inclusive),
when
minutes
is
used as the unit.
–
The interval is
an integer
ranging from 3
to 59 (inclusive),
when
seconds
is
used as the unit.
[Default value]
If the unit is
minute
, the default
value is
60 minutes
.
If the unit is
second
,
the default value is
30 seconds
.
NOTE
When the primary-
end model is 2200
V3, the resource type
is LUN, the unit can
only be
minutes
and
the interval is an
integer ranging from
15 to 1440
(inclusive).
OceanStor V3 Series
Remote Replication Feature Guide for Block
3 Configuring Remote Replication
Issue 06 (2018-01-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
54